21-3601E rev1.3 xL Simplified Installation Guide 7
Total current draw with the auxiliary and module bus must not exceed 1.0A
Europe
For units that include the mains transformer within the control cabinet.
INPUT: 230VAC, 0.26A, 60W, 50Hz
OUTPUT: Auxiliary, 12VDC, 1.0A
Module Bus, 12VDC, 750ma
Total current draw with the auxiliary and module bus must not exceed 1.0A
Power Supply Unit
Reference P/N 950-3650, 950-3651
North America
INPUT: 16.5VAC, 2.5A, 60W, 60Hz
OUTPUT:12VDC, 1.0A
Europe
For units that include the mains transformer within the control cabinet.
INPUT: 230VAC, 0.26A, 60W, 50Hz
OUTPUT: 12VDC, 1.0A
BATTERY STANDBY
The table below provides a guideline for the load and time that will be provided by a 7 or 17ahr battery. Ensure the
correct cabinet size is used as only the larger heavy grade enclosure (573-2912) can accommodate the 17Ahr
battery.
Time 7Ahr 17Ahr
24hours 280ma 600ma
30hours 230ma 500ma
72hours ------ 280ma
Installation requiring ULC listing requires that 24hours of back up power be provided in cases of failure of the Mains
AC.
Installations requiring UL listing for Bank Safe and Vaults requires that 72hours of backup power be provided in
case of failure of the Mains AC.
Installation requiring conformity to the European EN50131 series of standards requires that 30hours of backup
power be provided in case of failure of the Mains AC (note, for the U.K. the requirement is 24hours).
The 24hours and 30hours of backup will be provided after a minimum recharge time of 24hour.
The 72hours of backup will be provided after a minimum recharge time of 72hours.