22 MONITOR ISM™/AFx™ IP Connectivity Guide 22-9058 v2.1
3.3 Setting up the IP Interface (Central Monitoring with IP)
3.3.1 Setting the IP Module SIP (Security IP Receiver) Parameters
Programming the IP Interface board for panel reporting to the monitoring receiver
program.
• Put the IP Host board in Discovery mode and connect it with the IP Module Configuration
program as previously described.
• Press the “SIP” tab on the left side of the config screen.
• The SIP Setup Mode is defaulted to Disabled
. This mode must be set as No Firewall, for an
immediate connection to the Security IP (SIP) Receiver Software with the other settings left
defaulted. Modifications to the remainder settings are only necessary to:
• Change the UDP (Local Port).
• Use the firewall feature.
The selections are:
Setup
Mode
(Firewall specifics)
Default:
“Disabled”
• Disabled No communications with SIP.
• No Firewall
Ordinary communications with SIP and no restrictions on the SIP Receiver
address.
• Firewall
Communications with SIP is limited to the addresses specified in the Firewall settings.
Local Port # (UDP Port number of IP Module for SIP Receiver communications)
Default:
“24833”
• This value must be entered into SIP Receiver program “IP Port” column for the appropriate
panel(s).
Follow steps 1 – 6, section 2.3 if the IP Module is being programmed for the first time. This section
covers the recommended method for setting up a IP Module board using Discovery Mode and the IP
Module Configuration utility. Alternative methods are discussed in section 4.5.
If the IP Module was already programmed for a PCPanel connection, proceed
with IP Module SIP (Security IP Receiver) programming.
Reminder: Initial IP board set-up with IP Module config cannot be done across a WAN connection.
Slave Boards (for SIP): These boards (if present) do not need to be configured.