Access "Configuration Areas" as
described previously, and use the
Grid
/
Form
toolbar-button to select
your preferred 'view'.
In 'Forms' view, select the desired
Area at the bottom of the window.
Tip:
You can also use the 'Find' and 'Find
Next' buttons (binoculars) to search by name
(or 1
st
few characters--e.g., nam
).
Then, right-click a blank portion of the
form and select
Delete
. When asked
to confirm, select
Yes
.
(In Grid view, right-click the desired Area in
the list, and select
Delete
. When asked to
confirm, select
Yes
.)
Note:
The 1
st
area for each panel cannot be deleted
(i.e., each panel must have at least one area set up).
Pick-Lists (bottom of the Form)
-Panel Group
&
Panel
references (optional)
:
This is
where you select a specific panel-group and panel
in a multi-panel system where the 'tree' is
not
set to
show items on a panel-by-panel basis. For more
information on this feature, refer to "Other Desktop
Choices".
-Area:
This is where you select an area to view
or edit. This shows a reference number
assigned by the system, and the name of the
selected area, once defined;
"Offset" values for each panel determine whether
multi-
panel
sites will have consecutive versus
repeating area numbers. For details, refer to the
"Display Offsets" value under "System Panels and
Displayed Item-Numbers".
Top of the Form
- Name:
A suitable name for the area (e.g.,
"Warehouse").
Intrusion
(systems with monitored sensors)
- Stay on Fail to Exit:
The area will automatically
switch to 'Stay' mode if the user fails to exit after
arming the area (i.e., if an entry/exit door in the
area is not opened). This cannot be used in
conjunction with 'Auto Arm on Fail to Close'
(under " Scheduling ", to follow);
-Terminate Exit Delay:
The 'exit delay' will be
truncated when the door closes after the user
arms the area and exits.
This is typically for smaller facilities where you can
easily determine if others are still present. For a
larger site, area scheduling is recommended (see
" Scheduling ", to follow/below).
-Dual Custody:
Disarming this area will require
two authorized user's to enter their ID and/or
PIN (only one needed for arming).
Visitor cards set to require an escort cannot be used
with Dual Custody. Dual custody is also supported
pertaining to gaining entry at individual readers. For
details, look for the "Reader Mode" setting in the door-
configuration section.
- Auto Arm on Door Close:
The area will arm
automatically when any 'door' point in this area
closes (typ. used with bank vaults).
-------------------------
- Alarm on Fail to Exit:
An alarm will be
transmitted if the user fails to exit after arming
the area (i.e., if an entry/exit door in the area is
not opened);
- Siren Squawk On Arming:
The 'siren' outputs
for this area will be pulsed briefly when the area
is armed;
- Disarm Interlock Group:
Sets this as an
interlocked area. Of all areas with this selected,
only one can be disarmed at a time (except by a
service technician).
Delay Times
-Entry:
The duration that the monitoring of 'Entry'
points will be held/delayed to allow an
authorized entrant to disarm the area;
-Exit:
The duration that the monitoring of 'Exit'
points will be held/delayed to allow the user to
exit after arming the area.
UL-Listed Systems: These must be 45 seconds or
less for residential installations, and 60 seconds or
less for commercial installations.
-------------------------
Configuration Areas