MONITOR AFx™ Director V4.1 User's Guide
500-9041 v4.1
point number.
-------------------------
- Range:
This is the total range of input point
numbers associated with the specific
module/POD (as defined by the software when
each module is set up).
Tip:
The number in brackets, such as "(1)", pertains
to the location of the physical input-point connection
on the specific module.
- Point Type:
The type of sensor and/or the type
of monitoring to be used with this point (E/E
door, PIR, etc.), and to identify the input points
that are on the perimeter of an area. The
selections include many pre-defined types, plus
‘custom types 80-99’ that can be set up
manually.
Tip:
Pause the mouse cursor over a
point-type in the list to view its associated
characteristics.
To set up a garage/extended-delay input, or other
custom type of sensor, refer to "Input Points--Custom
Point Types".
EE Door: This pertains to entry/exit doors that are
monitored by the system, but
not
electronically
controlled for personnel access. To set up an access-
controlled door (and its dedicated inputs), refer to
"Doors, Readers, and Related Settings".
Similar to physical items in a system, custom point-
types pertain to an individual panel.
- Circuit Type:
The type of circuit/wiring used
with the input point / sensor;
Area
-Area:
The area that this point is associated with
(for doors adjoining two areas, see the next
item);
- Buffer Area
(EE Door points)
:
Where a door
adjoins two areas, select the second area here.
The system will apply appropriate entry/exit
delays whenever only one of the two areas is
fully armed (ON).