Unlock Time
- Standard:
This is the duration that the door will
unlock when access is granted for a typical
entrant/user.
- Challenged/Extended:
This is the duration that
the door will unlock when access is granted for a
user who is set for "Extended
Delay/Challenged".
Auto Unlock
- Schedule / "In Schedule" / "Out of
Schedule":
The schedule and conditions
required for the door to unlock automatically
based on a schedule.
If a schedule is selected, the times 'Outside' of the
schedule are treated in a similar manner to 'Inside' of
the schedule. (For example: You can have the door
unlocked inside of the active schedule, and also
unlocked after-hours, but only if/when the area is also
disarmed.)
To have the door simply re-lock at the closing time, set
the "In Schedule" value as desired, and set the "Out of
Schedule" value to "
Locked
".
To have the door unlocking follow the area arming-
state only, set the schedule to "
None
", and "In
Schedule" to either "
Area is Off
", or "
Area is
Stay/Off
", as desired.
If you do
not
want the door to unlock automatically
based on a schedule and/or the area arming-state, set
the "Schedule" to "
None
", and the 'In Schedule' value
to "
Locked
".
Circuit
With converted TDC/PDC door controllers, this setting
does not apply.
- Reader Tamper Circuit:
This is the type of
circuit/wiring used with the reader tamper circuit
for this door.
Not Required: This disables the reader tamper input
(i.e., the tamper input will not be monitored).
Converted TDC/PDC Door Controllers: These units
do not support dedicated/separate reader tamper
monitoring.
- Door Circuit:
This is the type of circuit/wiring
used with the door contact for this door.
Other
- Door Arming Level:
The area arming levels
for which the door is to be monitored.
Tip:
You may wish to use "Stay and On" with doors
used to enter the facility, and "On Only" for all doors
within the facility.
- Bi-Colour LED Mode:
Select this if the reader
at this door has a single bi-colour LED (instead
of the two separate LEDs). This setting
must
also be used if an 'arming station' is present.
Note:
Arming-station wiring differs from other readers
(ensure the proper installation instructions have been
followed).